Useful Flags And Control Bits - Omron C200H-ASC11 Manual

Ascii units
Hide thumbs Also See for C200H-ASC11:
Table of Contents

Advertisement

CPU Unit Error Indicators
9-3-2

Useful Flags and Control Bits

Special I/O Unit Error
Flags
C200H/HS
C200HX/HG/HE
AR 0000
SR 28200
AR 0001
SR 28201
AR 0002
SR 28202
AR 0003
SR 28203
AR 0004
SR 28204
AR 0005
SR 28205
AR 0006
SR 28206
AR 0007
SR 28207
AR 0008
SR 28208
AR 0009
SR 28209
---
SR 28210
---
SR 28211
---
SR 28212
---
SR 28213
---
SR 28214
---
SR 28215
Special I/O Unit Restart
Bits
The PC error flags in the following tables will indicate the following errors.
• Duplicated unit numbers on Special I/O Units
• Refreshing between the CPU Unit and Special I/O Unit didn't proceed
normally.
Flag address
CS1
Errors
A41800
A41801
A41802
A41803
A41804
A41805
A41806
A41807
A41808
A41809
A41810
A41811
A41812
A41813
A41814
A41815
Note *Of the C200HX/HG/HE CPU Units, used only in the C200HX/HG-CPU5
(Z)E C200HX/HG-CPU6
C200HX/HG/HE(-Z)
C200H/HS
CS1
To restart a Special I/O Unit, toggle (OFF → ON → OFF) the corresponding
Restart Bit shown in the following table. These bits can be used to restart the
Unit without turning off the power supply.
C200H/HS
AR 0100
AR 0101
AR 0102
AR 0103
AR 0104
AR 0105
AR 0106
AR 0107
AR 0108
Unit
Number
Duplication
A41100
ON when an error occurred in Unit 0.
A41101
ON when an error occurred in Unit 1.
A41102
ON when an error occurred in Unit 2.
A41103
ON when an error occurred in Unit 3.
A41104
ON when an error occurred in Unit 4.
A41105
ON when an error occurred in Unit 5.
A41106
ON when an error occurred in Unit 6.
A41107
ON when an error occurred in Unit 7.
A41108
ON when an error occurred in Unit 8.
A41109
ON when an error occurred in Unit 9.
A41110
ON when an error occurred in Unit A (10).*
A41111
ON when an error occurred in Unit B (11).*
A41112
ON when an error occurred in Unit C (12).*
A41113
ON when an error occurred in Unit D (13).*
A41114
ON when an error occurred in Unit E (14).*
A41115
ON when an error occurred in Unit F (15).*
- (Z)E.
@
Model
Bit address
C200HX/HG/HE
CS1
SR 28100
A50200 Restarts Unit 0.
SR 28101
A50201 Restarts Unit 1.
SR 28102
A50202 Restarts Unit 2.
SR 28103
A50203 Restarts Unit 3.
SR 28104
A50204 Restarts Unit 4.
SR 28105
A50205 Restarts Unit 5.
SR 28106
A50206 Restarts Unit 6.
SR 28107
A50207 Restarts Unit 7.
SR 28108
A50208 Restarts Unit 8.
Function
Flag address
SR 25415
ON when an error occurred in a
Special I/O Unit.
A40206
A40113
ON with the same unit number
has been assigned to more
than one Special I/O Unit.
Function
Section 9-3
-
@
Function
253

Advertisement