12.2.2.7
Test Operation
1
Press and hold the 3 buttons for
4 seconds or more simultaneously.
,
, ►
2
Select [Test run].
▲ ▼ →
3
Select [ON].
(The unit enters the test operation mode. Then, [TEST] turns on.)
▲ ▼ →
Press
.
4
Perform the test operation.
5
Finish the test operation.
Perform step 1 and 2, and then select [OFF] in step 3. ([TEST] display disappears.)
● The test operation can be performed in Heat or Cool mode.
● Temperature cannot be changed.
● The test operation mode is automatically turned off in 60 minutes. (To prevent continuous test operation)
● Outdoor units do not operate for approx. 3 minutes after the power is turned on or operation is stopped.
Attention
Do not use this mode for purposes other than the test operation.
(To prevent overload of the units)
Read the installation instructions supplied with the units.