Download Print this page
ElectrIQ eiQ60touchslimhe User Manual

ElectrIQ eiQ60touchslimhe User Manual

Touch control cooker hood

Advertisement

Quick Links

USER MANUAL
COOKER HOOD
TOUCH CONTROL COOKER HOOD
eiQ60touchslimhe/eiQ90touchslimhe
Thank you for choosing electriQ
Please read this user manual before using this
product and keep it safe for future reference.
Visit our page www.electriQ.co.uk for our entire product range
1

Advertisement

loading

Summary of Contents for ElectrIQ eiQ60touchslimhe

  • Page 1 USER MANUAL COOKER HOOD TOUCH CONTROL COOKER HOOD eiQ60touchslimhe/eiQ90touchslimhe Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference. Visit our page www.electriQ.co.uk for our entire product range...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRODUCT OVERVIEW VENTILATION INSTALLATION OPERATION FILTER CLEANING AND REPLACEMENT BULB REPLACEMENT CLEANING AND MAINTENANCE TROUBLESHOOTING SUPPORT PRODUCT FICHE...
  • Page 3: Safety

    SAFETY PRECAUTIONS Whilst this product is compliant with all safety requirements, incorrect or inappropriate use can lead to both personal injury and potential damage to property. Please read the contents of this instruction booklet thoroughly before fitting or using this appliance. •...
  • Page 4 • The minimum distance between the surface of the hob and the lowest part of the hood should be at least 65cm. A distance of between 65cm and 75cm gives peak efficiency. • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
  • Page 5: Product Overview

    PRODUCT OVERVIEW...
  • Page 6: Installation

    INSTALLATION (VENT OUTSIDE) MOUNTING OF THE V-FLAP If the cooker hood does not have an assembled V-flap 1, you should mount the half- parts to its body.The images only show an example of how to mount the V-flap,the outlet may be various according to different models and configuration. To mount the V-flap 1 you should: 1.
  • Page 7 OPTIONS FOR VENTILATION This hood can be set up for either external venting or recirculation of the air. The type of setup should be decided before commencing installation. INSTALLATION If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminum, flexible pipe or non- flammable material with an interior diameter of 150mm) 1.
  • Page 8 4. Put the v-flaps and converter onto the hood, fix the expansion pipe (not supplied) with cable tie on the outlet.Then hang the hood on to the hook. See pic 3. 5. Fix the outside chimney bracket on the outside chimney with 2 pcs ST4*8mm screws, and be sure that the inside chimney can be adjusted the height in it freely.
  • Page 9 HINTS FOR EXHAUST DUCT INSTALLATION The following rules must be strictly followed to obtain optimal air extraction: • Keep expansion pipe short and straight. • Do not reduce the size or restrict expansion pipe. • When using expansion pipe always install the pipe pulled taut to minimize pressure loss.
  • Page 10 INSTALLING GREASE MESH FILTERS • To install filters for the following four steps. • Angle the filter into slots at the back of the hood. • Push the button on handle of the filter. • Release the handle once the filter fits into a resting position.
  • Page 11: Bulb Replacement

    BULB REPLACEMENT Before changing the bulb, ensure the hood is turned off and the power is disconnected before attempting to change the bulb. Wait until the flitting has cooled down before commencing replacement. • Open the LED light plate assembly and take away the grease filter.See pic 1. •...
  • Page 12: Troubleshooting

    TROUBLESHOOTING Fault Possible Cause Solution Fan switch turned off Select a fan switch position. Light on, but motor Fan switch failed Contact service center. does not work Motor failed Contact service center. House fuses blown Reset/Replace fuses. Light does not work, motor does Power cord loose or Refit cord to power outlet.
  • Page 13: Support

    At the end of life, the appliance should not be disposed of with household waste. Check with your Local Authority or retailer for recycling advice. electriQ UK SUPPORT www.electriQ.co.uk/support Call: 0330 390 3061 Office hours: 9AM - 5PM Monday to Friday...
  • Page 14: Product Fiche

    PRODUCT FICHE Model Identification eiQ60TOUCHSLIMHE eiQ90TOUCHSLIMHE Symbol Value Unit Annual Energy AEChood 16.1 kWh/A Consumption Standard Annual Energy SAEChood 51.2 kWh/a Consumption Time increase factor Fluid Dynamic Efficiency FDEhood 37.9 Energy Efficiency Index EEIhood 31.4 Measured air flow rate at QBEP 319.1...

This manual is also suitable for:

Eiq90touchslimhe