Parameter Modifi Cation - gefran SIEIDrive ADV200 DC Series Quick Start Up Manual

Field oriented vector ac drive for syncronous/asyncronous motors
Table of Contents

Advertisement

This function permits access to any parameter entering only the software number
of the parameter (PAR).
When the parameter reached by the "Goto" command is displayed, it is possible
to navigate all the parameters forming part of the same group using the ▲ and ▼
keys.
Pressing the ► key returns to the "Goto" function.
To exit the "Goto" function, press the ► key.
6.3 Parameter modifi cation
To enter parameter modifi cation mode, press the E key when the parameter to be
modifi ed is displayed.
To save the value of the parameter, following modifi cation, press the E key again.
To save permanently, see
Note !
To exit from modifi cation mode without saving the value, press the ESC key.
The operations to be carried out to modify the value depend on the type of the
parameter, as described below.
For further information about the type of parameters displayed, see chapter Parameters List (ADV200
Note !
FP manual).
Numeric parameters
T+
T -
13 DIGITAL OUTPUTS
14 ANALOG INPUTS
15 ANALOG OUTPUTS
16 MOTOR DATA
When E is pressed to access modifi cation mode, the cursor is activated on the
digit corresponding to the unit.
Using the ◄ and ► keys, the cursor can be moved to all the digits, including trail-
ing zeros that are normally not displayed.
With the ▲ and ▼ keys, the digit under the cursor is increased or decreased.
Press E to confi rm the modifi cation or ESC to cancel.
Binary parameters (BIT type)
The parameter may assume only two states which are indicated as OFF-ON or
0-1.
T+
T -
10 SPEED MONITOR FUNC
11 COMMANDS
12 DIGITAL INPUTS
13 DIGITAL OUTPUTS
Pressing E, modifi cation mode is activated. The entire line is displayed in reverse.
Use the ▲ and ▼ keys to move from one state to another.
Press E to confi rm the modifi cation or ESC to cancel.
paragraph
EN
LOC
ILim
n:0
AL
EN
LOC
ILim
n:0
AL
X 5
ADV200 • Quick start up guide - Specification and installation
6.4.
T+
T-
EN
LOC
ILim
n:0
AL
1 6 . 0 1
PA R :
2 0 0 0
Rated voltage
400
+
V
Def:
+400
T+
T-
EN
LOC
ILim
n:0
AL
1 3 . 0 5
PA R :
1 3 3 0
Di g out 1 inversion
ON
T+
T-
EN
LOC
ILim
1 6 . 0 1
PA R :
Rated voltage
E
000000400
+
Def:
+400
T+
T-
EN
LOC
ILim
1 3 . 0 5
PA R :
Di g out 1 inversion
E
OFF
n:0
AL
2 0 0 0
V
n:0
AL
1 3 3 0
61