6.2.3 Scanning of the parameters

T+
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
6.2.4 List of the last parameters modifi ed
Pressing the CUST key, a list containing the last 10 parameters modifi ed is ac-
cessed. One parameter at a time is displayed and the list can be scrolled using
the ▲ and ▼ keys.
To exit this list, press the ► key.

6.2.5 "Goto parameter" function

Pressing the CUST key twice, or once if already in the "List of modifi ed param-
eters", the "Goto parameter" is activated.
60
Description of the parameter.
Depends on the type of parameter:
● Numeric parameter: displays the numeric value of the parameter, in the
format required, and unit of measurement (fi gure A).
● Binary selection: the parameter may assume only 2 states, indicated as
OFF-ON or 0 - 1 (fi gure B).
● LINK type parameter: displays the description of the parameter set from the
selection list (fi gure C).
● ENUM type parameter: displays the description of the selection (fi gure D)
● Command: displays the method of execution of the command (fi gure E)
In this position, the following may be displayed:
● Numeric parameter: displays the default, minimum and maximum values
of the parameter. These values are displayed in sequence pressing the ► key
(figure A).
● LINK type parameter: displays the number (PAR) of the parameter set (fi g-
ure C) .
● ENUM type parameter: displays the numeric value corresponding to the cur-
rent selection (fi gure D).
● Command: in the case of an error in the command, indicates that ESC must
be pressed to terminate the command (figure G).
● Messages and error conditions (figure F):
Param read only
attempt to modify a read-only parameter
Password active
the parameter protection password is active
Drive enabled
attempt to modify a non-modifi able parameter with the drive enabled
Input value too high the value entered too high
Input value too low the value entered too low
Out of range
attempt to insert a value outside the min. and max. limits
T -
EN
LOC
ILim
n:0
AL
ADV200 • Quick start up guide - Specification and installation
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 0 1
PA R :
2 5 0
Out p ut current
0. 3
+
A
. . .
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 2 2
PA R :
1 4 0 0
Digital out ut X mon
p
0
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 0 2
PA R :
2 5 2
Out ut volta e
p
g
1
-
V
. . .