3.2
Temperature
storage ____________________ -25...+55°C (-13...+131°F), class 1K4 per EN50178
transport ___________________ -25...+70°C (-13...+158°F), class 2K3 per EN50178
Air humidity
storage ____________________ 5% to 95 %, 1 g/m
transport ___________________ 95 % (3), 60 g/m
Air pressure:
storage ____________________ [kPa] 86 to 106 (class 1K4 as per EN50178)
transport ___________________ [kPa] 70 to 106 (class 2K3 as per EN50178)
(3)
(4)
The drive is suitable for use under the environmental service conditions (climate,
mechanical, pollution, etc.) defi ned as usual service conditions according to
Attention
EN61800-2.
Permissible Environmental Conditions
A light condensation of moisture may occur for a short time occasionally if the device is not in operation
(class 2K3 as per EN50178)
Greatest relative air humidity occurs with the temperature @ 40°C (104°F) or if the temperature of the
device is brought suddenly from -25 ...+30°C (-13°...+86°F).
Greatest absolute air humidity if the device is brought suddenly from 70...15°C (158°...59°F).
ADV200 • Quick start up guide - Specification and installation
-20...+55°C (-4...+131°F), for devices with keypad
-20...+60°C (-4...+140°F), for devices with keypad
to 29 g/m
3
(4)
3
(class 1K3 as per EN50178)
3
15