External Lcd Diagnostics Handset - Lenovo ThinkEdge SE450 Maintenance Manual

Table of Contents

Advertisement

Use this blue LED to visually locate the server among other servers. This LED is also used as a presence
detection button. You can use Lenovo XClarity Administrator to light this LED remotely. The states of the
identification LED are as follows:
Off: Presence detection off.
Flashing rapidly (4 times per second): (on XCC firmware version 3.10 or later) The server is not activated
yet and has no power permission.
Flashing slowly (once per second): Presence detection is on.
On: Presence detection is on.
5
System-error LED (yellow)
When this yellow LED is lit, it indicates that one ore more system errors have occurred. This LED can be
controlled by the XCC. Detailed information is available on the External LCD diagnostics handset (see
"External LCD diagnostics handset" on page

External LCD diagnostics handset

The external LCD diagnostics handset is an external device that is connected to the server with a cable, and
it allows quick access to system information such as errors, system status, firmware, network, and health
information.
Location of the external LCD diagnostics handset
The external LCD diagnostics handset is connected to the
server with an external cable.
Note: When unplugging the external handset, see the following instructions: ❶ Press the plastic clip on the
plug forward.
❷ Hold the clip and remove the cable from the connector.
ThinkEdge SE450 Maintenance Manual
20
20).
Location
Callouts
External LCD diagnostics handset
1
Magnetic bottom
2
With this component, the diagnostic handset can be
attached to the top or side of the rack with hands
spared for service tasks.
External diagnostics connector
3
This connector is located on the front of the server,
and is used to connect an external LCD diagnostics
handset.