Diagnose - Real Time Data - Rational SelfCookingCenter SCC Training Manual

Table of Contents

Advertisement

Diagnose - Real Time Data

Real time data - Sensors
Cabinet B1
Quenching B2
Humidity B4
Steam Generator B5
Core Temp B3-1 (tip)
Core Temp B3-2
Core Temp B3-3
Core Temp B3-4
Core Temp B3-5
Core Temp B3-6 (shaft)
Temperature PCB
Real time data - Clima
Clima Status RPM 1L
Clima Status RPM 1R
Clima Status RPM 2L
Clima Status RPM 2R
Clima Status RPM 3L
Clima Status RPM 3R
Clima Status RPM 4L
Clima Status RPM 4R
Clima valve Y5
Clima Out P1
Clima Humidity
Real time data - Water, CleanJet / Care, Motor / Switch
Filling solenoid Y1
Quenching solenoid Y2
Moistening solenoid Y3
CDS Sensor S11
Level Electrode S2
SC-Automatic
Volume Steam generator
SC-pump
CleanJet Pump M6
Drain valve motor M7
Micro switch drain valve
S12
Care pump M12
Solenoid valve care Y4
Battery voltage
Door Contact S3
Motor Table/Floor M1
Motor Floor M2
Hot air
Steam
Act. Temperature
Max Tempera-
ture
Status
Dry
500 rpm
Dry X Pa
500 rpm
Dry X Pa
1000 rpm
Dry X Pa
1000 rpm
Dry X Pa
1450 rpm
Dry X Pa
1450 rpm
Dry X Pa
1550 rpm
Dry X Pa
1550 rpm
Dry X Pa
"open" or "closed"
x.x Volt
x %
Status
Status
"on" or "off"
"on" or "off"
"on" or "off"
1000
"water" or "no water"
Actual X min
Run time X sec.
Norm X l
Fill X l
„puls" or „continuous"
"on" or "off"
"on" or "off"
0 or 1
"on" or "off"
"on" or "off"
Actual value
"open" or "closed"
L/R
X 1/Min
L/R
X 1/Min
0% or 50% or 100%
GAS: X uA
0% or 50% or 100%
GAS: X uA
Acvcepted Tole-
rance
Wet
Wet X Pa
Wet X Pa
Wet X Pa
Wet X Pa
Wet X Pa
Wet X Pa
Wet X Pa
Wet X Pa
Status
Set time X min
Calccheck X l
- 65 -
Time max temperature reached
combi
Combi X Pa
Combi X Pa
Combi X Pa
Combi X Pa
Combi X Pa
Combi X Pa
Combi X Pa
Combi X Pa
Status
V08 en, SCC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents