Cleanjet/CareControl SCC

1
2
3
Cleanjet programs:
Rinse without tabs:
Rinse:
Interim cleaning:
Light, Safe, Medium, Strong:
Using any of the Cleanjet programs: Quick, Save, Medium or Strong will reset the bars of the Display Clean to 1
green bar (starting with software version 05-00-09).
CleanJet +Care can only be started when the cabinet temperature is below 50°C (122°F).
In case an error 27, 40-44 is existing, Cleanjet*Care can not be started.
(ref. to error messages). After repair of 40 - 44, 110-120 a Rinse program (not rinse without tabs) or
full clean program must be run before another cleaning cycle is possible again. With software ver-
sion 07-00-08 reset error by pressing Function test CleanJet in Service level.
In case an error 110 or 120 is existing, only an abort cycle of 27 minutes is offered and must be run
successfully before the unit can be used again.
The condition of the indication depends on:
the use of the unit
the cleaning behaviour of the customer
the degree of scale in the steam generator (see information CDS).
Display Maintenance status - long term status display
1:
very good care - arrow position green
2:
medium care - arrow position yellow
3:
neglected care - arrow position red
The request for Clean+Care has been neglected several times.
Only regular cleaning will reduce the display to one green bar again.
Display Cleanliness - short term / daily status display
Actual dirt status
1: arrow position green - no cleaning necessary
2: arrow position yellow - CleanJet request will show soon
3: arrow position red - Cleaning urgently required
CleanJet request is dependent on the usage pattern of the unit:
- SCC processes, - manual modes, - cooking programs, - duration, - temperatures
For demonstration of CleanJet+Care to the customer switch the unit first to Demo
mode followed by switching off and on.
Now you can demonstrate the behaviour of the Maintenance and Cleanliness bar
by pressing on the individual bars.
1) Cleaner Tabs: 56.00.210
2) Rinse Tabs:
56.00.211
2) Care Tabs:
56.00.562
The use of Rinse tab 56.00.211 in a SCC unit index G - I will lead to a blocked Care
pump and Service 40 error.
Each Cleanjet program starts with a components test
Fresh water without chemical is pumped by M6 through the cabinet.
Care chemical is pumped by M12 via the steam generator into the control
box and by M6 through the cabinet
Cleaner chemical is pumped through the cabinet by M6
Cleaner chemical is pumped through the cabinet by M6. After that Care
chemical is pumped by M12 into the steam generator for descaling and part
of it into the control box and by M6 through the cabinet
Programs have different duration.
- for SCC index E, G, H and index I units
- for CM_P index I units
- only for SCC index E and CM_P index I units
- only for SCC index G - I units
- 59 -
V08 en, SCC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents