Cm_P - Function Test - F - Rational SelfCookingCenter SCC Training Manual

Table of Contents

Advertisement

CM_P - Function test - F

Function test
1
Switch unit ON
2
On operator PCB set DIP switch 2 to „ON" position
3
Select function test with timer dial:
Activation of manual calibration
Function test
bini - ball valve initialization, to start press core probe key.
4
Activate function test by pressing core temperature key
5
Select desired step with timer dial.
6
Activate selected step with timer key.
7
Activate component with core temperature key.
To de-activate function test set DIP switch 2 to „OFF" position.
8
Switch unit off and on again.
Function
Steam 50%,
Electric unit
Steam 100%
Electric unit
Hot air 50%
Electric unit
Hot air 100%
Electric unit
Steam Gas unit
Hot air Gas unit
table / floor top
Hot air Gas
floor unit bottom
Motor top MAX rpm
Table and floor models
Motor top MAX rpm
Table and floor models
Motor top MIN rpm
Table and floor models
Motor top MIN rpm
Table and floor models
Motor bottom MAX rpm
floor models only
Motor bottom MAX rpm
floor models only
V08 en, SCC
Connection
Cabinet
PCB
display
actual temp.B5
X24:(1-2)
steam generator
X24:(1-2)+(5-
actual temp.B5
6)
steam generator
actual temp.B1
X24:(7-8)
cabinet
X24:(7-8)+(3-
actual temp.B1
4)
cabinet
actual temp.B5
BUS
B5 steam generator
actual temp.B1
BUS
cabinet
actual temp.B1
BUS
cabinet
BUS
Set rpm
BUS
Set rpm
BUS
Set rpm
BUS
Set rpm
BUS
Set rpm
BUS
Set rpm
- 84 -
Time
Comment
display
Gas:
1 / 0
no function
Gas:
1 / 0
no function
Gas:
1 / 0
no function
Gas:
1 / 0
no function
Electric:
1 / 0
no function
Electric:
1 / 0
no function
Electric:
1 / 0
no function
Act. rpm
clockwise
Act. rpm
anti clockwise
Act. rpm
clockwise
Act. rpm
anti clockwise
clockwise
Act. rpm
201 / 202 only
anti clockwise
Act. rpm
201 / 202 only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents