Additional function
CALC - Descaling steam generator
Caution!
Descaler shall ONLY be filled through the steam inlet port inside the interior cabinet!
Protective clothing must be worn.
Interior cabinet temperature must be below 40°C (104°F);
Steam generator will be emptied, refilled and emptied again;
„CALC" „FILL": prompt to fill descaler into the steam generator;
30 second waiting time (to rinse cabinet with water);
"door": prompt to close cabinet door;
45 minutes reaction time for the chemical,
"CALC": Steam generator will be rinsed twice and refilled again;
Steam mode for 15 minutes
"END" and buzzer for 20 seconds
Display:

CM_P Index I/ CM Index I

CM_P with CleanJet
PCB
All CM_P with index I have a new PCB 42.00.272
Door:
All CM_P units 60 - 202 are equipped with a new door with 2 glass panes and halogen light
inside the cabinet. (without LED light, only halogen light in the cabinet
Only the CM_P XS (60) has a LED light in the door like SCC_XS (without level indication, without halogen light).
CM_P XS:
In order to connect the unit to the drinking water supply, water protection according EN 1717 must be ensured by
installing a double check valve, a type CA system divider or similar in the fresh water line.
CM 61 - 101
The basic model CM with index I has the identical construction as CM_P index H. It is only available in size 61 and
101 (without Cleanjet) and only with right hinged door.
V08 en, SCC
Call service partner to descale steam generator
Hand shower:
All CM and CM_P with index I get a new hand shower roll guide
(56.00.061).