CM_P - Basic settings - SE

Switch unit OFF and ON again after making any changes!
Adjustments should only be done with SE4, 5, 8 and 20. Do not alter other settings!
Select desired step with timer dial
(fan motor and heating elements are automatically OFF)
Activate selected step with timer key
Steam heating time since last SC-Automatic
Press the time and core keys simultaneously for 5 seconds to set steam heating time (SE2) to
preset steam heating time plus 1 minute (default 45+1min) => test function for SC-Automat-
+
ic
Preset Steam heating time until SC-Automatic (default 60min)
Press time key and adjust preset steam heating time from 20 - 120 minutes with timer dial
+
Flushing time SC-Automatic (default 45 seconds)
Press time key and adjust flushing time of SC- Automatic from 30 - 90 seconds with timer
+
dial
Operation SC pump (oFF - continuous or on - pulsing)
Press time key and select „on" or „oFF" with timer dial
+
Show mode (on - oFF)
Press time key and select „on" or „oFF" with timer dial;
keep time key pressed and press Core key for 1 sec, release core key before
+
releasing time key,
Setting of quenching temperature hot air.
+
Press time key and set temperature with temperature dial. Setting: 90°C, possible 75°-105°.
Keep time key pressed and confirm with Core key.
Setting of quenching temperature wet modes (Steam, Combi, Finishing)
+
Press time key and set temperature with temperature dial. Setting: 80°C, possible 65°-95°.
Keep time key pressed and confirm with Core key.
Setting new gas type (G20, G25, G30, G31, 13A)
Press time key, keep it pressed and select new gas type with timer dial Confirm new gas type
by pressing core temperature key once. Corresponding gas blower speed is automatically
adjusted
+
NOTE: After changing gas type a flue gas analysis must be carried out via
function test.
Nominal length of CO2 screw in mm on gas valve after gas type modification / changing gas
valve
Press time key, keep it pressed and select with timer dial "ST" for steam, "HA1" for hot air top
or "HA2" for hot air bottom (only 201/202) with timer dial;
+
Average length in mm of CO2 screw on gas valve is shown on timer display