Mounting XV2-2T/XV2-2T1

The XV2-2T/XV2-2T1 units are mounted either by using the wall mounting or pole mounting method.
Wall mounting
The XV2-2T/XV2-2T1 units can be mounted to any wall by using two screws with corresponding wall
anchors. To mount the XV2-2T/XV2-2T1 unit on the wall, perform the following steps:
1. Drill two holes of each Ø 6 mm (Ø0.25" Inch) on the wall where you want to mount the XV2-
2T/XV2-2T1 AP.
2.
Press fit the plastic anchor and assemble fastener.
3.
Leave 5mm to 6mm gap between the wall and the fastener head, as shwon in below figure.
4.
Use the four mounting slots given on the back of the radio to mount it on the wall.
5.
Make sure that four screws are attached to the back side of the XV2-2T/XV2-2T1 unit. Do not
tighten the screws, completely.