Komatsu PC138US-11 Operation & Maintenance Manual page 203

Hydraulic excavator
Table of Contents

Advertisement

OPERATION
6.
Add oil through oil filler port (F) of the hydraulic tank until
the oil level comes between levels H and L of sight gauge
(G).
NOTICE
Do not add oil above H line. It may damage the oil cir-
cuit and cause the oil to spurt out.
If oil has been refilled exceeding H level, swing the up-
per structure until drain plug (P) beneath the hydraulic
tank comes between the right and left tracks. Stop the
engine. After the hydraulic oil has been cooled down,
remove cover (1) and drain the excess oil through
drain plug (P) to the container for receiving the oil.
REMARK
The oil level varies with the oil temperature. Use the fol-
lowing as a guide for check.
Before starting operation: Between H and L levels
(Oil temperature 10 to 30 °C)
Normal operation: Around H Level
(Oil temperature 50 to 80 °C)
METHOD FOR INSTALLING HYDRAULIC TANK OIL FILLER CAP
If the oil filler cap is inserted in reverse, it only rotates by approximately 1/4 turns and cannot be locked.
Install the oil filler cap according to the following procedure.
1.
Match the ▲ marks (1) on both of the oil filler cap and the
tank, and insert it.
2.
Rotate the oil filler cap clockwise, and lock it with the key.
The ▲ mark (1) on the oil filler cap matches with the key
mark on the tank.
MACHINE OPERATIONS AND CONTROLS
CAUTION
k
WENAM00111
3-133

Advertisement