OPERATION
"SCR Information" screen message (4): "1 Please inspect
and maintain SCR system."
Move the machine to the safe place and contact your Ko-
matsu Distributor.
If operation continues for 1 hour after "Warning" started
without taking any actions instructed by the Action Level
table, Inducement advances to "Escalated Warning".
Escalated Warning:
The audible alert sounds in repetition of "three beeps and
a pause".
The DEF system caution lamp (1) lights up in yellow.
If operation continues for 1 hour after "Warning" started
without taking any actions instructed by the Action Level
table, Inducement advances to "Escalated Warning".
Press F6 to display the "SCR Information" screen.
"SCR Information" screen message (4): "2 Without treat-
ment, engine power will be derated."
Move the machine to the safe place and contact your Ko-
matsu Distributor.
The duration of "Escalated Warning" is 1 hour. The remain-
ing time (Minutes) to "Mild Inducement" is displayed in the
column (5) of the "SCR Information" screen.
In "Mild Inducement", engine performance will be derated.
Mild Inducement:
The audible alert sounds in short and sharp beeps.
The DEF system caution lamp (1) lights up in red.
Action level "L03" lights up in red at action level display (2)
and stays on.
Press F6 to display the "SCR Information" screen.
"SCR Information" screen message (4): "3 Engine power is
under deration."
Due to the engine power deration, capability of the ma-
chine will be limited.
Move the machine to the safe place and contact your Ko-
matsu Distributor.
The duration of "Mild Inducement" is 1 hour. The remaining
time (Minutes) to "Severe Inducement" is displayed in the
column (5) of the "SCR Information" screen.
In "Severe Inducement", engine power will be derated fur-
ther.