Komatsu PC138US-11 Operation & Maintenance Manual page 138

Hydraulic excavator
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
1.
On "Breaker Setting" screen, select a breaker to change its
name, then press switch F6.
2.
The "Breaker Name Setting" screen is displayed.
On the "Breaker Name Setting" screen, you can perform
the following operations with switches F1 to F6.
F1: "CLEAR" Clears all the letters. (If some letters are left.)
F1: "DEFAULT" Displays the initial name. (If all the letters
are deleted.)
F2: Moves to the right letter.
F3: Moves to the next alphabet, numeral, or symbol.
F4: Moves to the previous alphabet, numeral, or symbol.
F5: Returns the screen to the "Breaker Setting" screen without changing the name.
F6: Enters the change and returns the screen to the "Breaker Setting" screen.
Changing Breaker Oil Flow Rate Setting
1.
On "Breaker Setting" screen, select a breaker to change its
oil flow, then press switch F2.
2.
The "Breaker Oil Flow Rate Setting" screen is displayed.
On the "Breaker Oil Flow Rate Setting" screen, you can
perform the following operations with switches F3 to F6.
F3: Decreases the flow rate by 1 level.
F4: Increases the flow by 1 level.
F5: Returns the screen to the "Breaker Setting" screen
without changing the oil flow.
F6: Enters the oil flow rate setting and returns the screen
to the "Breaker Setting screen".
(X): Present oil flow setting
(Y): Min. oil flow for adjustment
(Z): Max. oil flow for adjustment
ATTACHMENT SETTING
On machines ready for installation of attachment, you can adjust the oil flow rate in ATT/P mode and ATT/E
mode to match the attachment on the "Attachment Setting" menu.
For machines that have no attachment, the "Attachment Setting" menu is not displayed.