Komatsu PC138US-11 Operation & Maintenance Manual page 186

Hydraulic excavator
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
When manual stationary regeneration is not activated even af-
ter you push the switch F6, return to the normal screen. Then
push the switch F5, and follow the instructions shown on the
screen.
Manual stationary regeneration may continue for over 40 mi-
nutes. Do not operate any screen switches, fuel control dial, etc
before until regeneration is completed.
PROCEDURE FOR SETTING AFTERTREATMENT DEVICES-REGENERATION
DISABLE
If necessary, it is possible to disable automatic regeneration. Also, it is possible to stop regeneration in progress.
Procedures to disable automatic regeneration
1.
When the aftertreatment devices regeneration display (1)
is not lighting on the standard screen, push F6 on the
standard screen.
2.
Use F1 and F2 to select the "Aftertreatment Devices Re-
generation" menu (C) and display the "Aftertreatment Devi-
ces Regeneration" screen.
3.
With regeneration disable highlighted, push function switch
F6 to disable regeneration.
3-116
WENAM00111
OPERATION

Advertisement

Table of Contents
loading

Table of Contents