4.
Press F6 while the "Engine power Recovery" window is
displayed.
Temporary Restoration from Inducement is activated and
engine power deration is relieved to the deration of "Mild
Inducement" for the maximum of 30 minutes as long as
there is sufficient remaining time to "Final Inducement".
Note that whenever Inducement advances to "Final In-
ducement" Temporary Restoration from Inducement will be
turned off.
The remaining time (minutes/seconds) of "Temporary Re-
storation from Inducement" is displayed in the column (2)
on the "SCR Information" screen.
If it is decided NOT to activate "Temporary Restoration from Inducement" after having progressed to the "Engine
Power Recovery" window, follow the steps explained in this section.
To deactivate "Temporary Restoration from Inducement" function.
1.
Press F5 while the "Engine Power Recovery" window is
displayed.
This procedure is split from procedure 4 in "Temporary Re-
storation from Inducement".
"SCR Information" screen is displayed.