NAPCO Gemini GEM-P1632 Programming Instructions Manual page 50

Global panel communicator
Table of Contents

Advertisement

Page 50
WI897B 8/98
Auto-Reset; Auto-Reset After Burglary Output Timeout
If a zone detects an alarm condition and is selected for "Auto-Reset" (Address 0507, 0562, 0617, 0672), it will automatically rearm itself
as soon as the alarm condition is cleared. Auto-Reset may be delayed to occur after the Burglary Output timeout period by selecting
"Auto-Reset After Burglary Output Timeout" (Address 0719) and "Auto-Reset" . Zones that are not programmed for "Auto-Reset" will not
be capable of signaling another alarm until (a) the cause of the alarm has been corrected and (b) the control panel is disarmed. Also
see Swinger Shutdown.
Auxiliary Relay See Alarm Outputs
Backup Report on Telco 2
If "Backup Reporting on Telco 2" (Address 0394) is selected and the communicator does not reach the first telephone number after two
attempts, seven attempts will be made to reach the second telephone number. Enter Subscriber Identification Numbers for Telephone
2 and other information required for Telephone 2. Also program Backup Report on Telco 2. Any zone programmed to report to Telco 1
will backup report to Telco 2. Note: Subscriber Identification Numbers for both Telephones 1 and 2 must be entered, even if they are
the same.
Battery
12Vdc standby power source in the control panel is used to provide backup protection in the event of a power loss. The battery is an
integral part of the system and must be installed, even if ac power is present. Change the battery every 5 years or as required.
Bell Control
In any system, the ability to silence any combination of alarm devices (outputs) initiated from any area. Bell Control must be
programmed for all systems to be able to silence an alarm. For example, in a two-area system, each area could be programmed to
silence only those alarms initiated within its own area; or both areas could be programmed to silence an alarm initiated from either area.
Burglary Output See Alarm Outputs
Bus Failure
Communication failure on the 4-wire bus will cause a system trouble and a report to the central station. Program System Trouble
Reports and Report Codes for the 4-Wire Bus.
Call Waiting See Disable Call Waiting
Callback-Method Download; Answering Machine Pickup Without Line Seizure; Disable Callback Download (Required for UL
installations); 2nd Call Download (Required for UL installations); Disable Function-Mode Download; Number of Rings Before
Pickup
Data may be downloaded remotely to the panel after a programmed number of rings (3 to 15) and a control-panel confirmation call-
back. Program the "Number of Rings" (Address 1183); if not programmed, the panel will pick up after 15 rings.
This method will accommodate an answering machine at the site. "2nd Call Download" (Address 0722) must not be programmed.)
The answering machine will pick up on its programmed number of rings, as usual. Note: The number of rings programmed into the
panel must exceed that of the answering machine.
Program "Disable Callback Download" (Address 0720) to prevent unauthorized downloading to an unattended panel. Program
"Disable Answering Machine Download" to inhibit downloading to a telephone connected to an answering machine. Program "Disable
Function-Mode Download" (Address 0720) to prevent downloading at the keypad.
Cancel Next Test Timer Report on Any Report See Test Timer
Chime (Displays "MONITOR" on GEM-RP2ASe2 Keypads)
This annunciator feature may be used on any zone to sound a tone at the keypad while disarmed when the zone goes into trouble.
Access the ACTIVATE CHIME function (Easy Menu Driven Program Mode) to enable or disable the Chime Mode. This feature is pro-
grammable by zone (Address 0509, 0564, 0619, 0674) and "Chime Timeout" (Address 0716). A time must be programmed for the
chime to function.
Clear Program
Caution: Erases the dealer program. Use this feature to start a new customized default program. Access Address Location 1197, then
press the
button.
NAPCO Security Systems
GEM-P1632 Programming Instructions

Hide quick links:

Advertisement

Table of Contents
loading