Application Function 5
Characteristic
Typical applications
Type of outputs of sensor/device providing the input signal
for application function
S## terminals to be connected
Dynamization
Signal interlock monitoring
Synchronization of safety-related inputs
Wiring of the inputs for sensors/devices with two PNP outputs
HR9Z-B2200 8/2020
Value/Description
Monitoring of proximity switches
Two PNP outputs
S12 and S13 for sensor/device A
S22 and S23 for sensor/device B
S32 and S33 for sensor/device C
S42 and S43 for sensor/device D
S52 and S53 for sensor/device E
S62 and S63 for sensor/device F
If less than 6 safety-related inputs are used, the terminals
S#1, S#2 and S#3 of the unused safety-related inputs
must be bridged (example: sensor/device F not
connected: S61, S62 and S63 bridged).
Do not configure a start function with startup test if less
than 6 safety-related inputs are used.
No
Between terminals S12 and S13
Between terminals S22 and S23
Between terminals S32 and S33
Between terminals S42 and S43
Between terminals S52 and S53
Between terminals S62 and S63
No