Functions

Application Functions

Introduction
The following sections provide an overview of the available application functions and a detailed
listing of requirements and values of each of the application functions. The chapter Configuration
(see page
80) describes the configuration procedure by means of the selectors of the device.
Overview of Application Functions
Typical applications
Monitoring of Emergency Stop
circuits as per ISO 13850 and
IEC 60204-1, stop category 0
Monitoring of guards as per
ISO 14119/14120 with
electrical switches
Monitoring of guards as per
ISO 14119/14120 with
electrical switches
Monitoring of guards as per
ISO 14119/14120 with coded
magnetic switches
Monitoring of proximity
switches
Monitoring of proximity
switches
Monitoring of electro-sensitive
protective equipment such as
type 4 light curtains as per
IEC 61496-1
Monitoring of RFID sensors
58
Type of outputs of sensor/device
providing the input signal for
application function
Normally open, normally closed
and/or changeover outputs
Two PNP outputs
OSSD (Output Signal Switching
Device) outputs
Synchro
Dynami
Application
nization
zation
Function
Selector
No
Yes
Position 1
(see page
Yes
Yes
Position 2
(see page
Yes
Yes
Position 3
(see page
Yes
Yes
Position 4
(see page
No
No
Position 5
(see page
Yes
No
Position 6
(see page
No
No
Position 7
(see page
Yes
No
Position 8
(see page
HR9Z-B2200 8/2020
59)
61)
63)
65)
67)
68)
70)
71)

Advertisement