IDEC HR6S-DN Instruction Manual page 68

Safety module
Hide thumbs Also See for HR6S-DN:
Table of Contents

Advertisement

Functions
Application Function 6
Characteristic
Typical applications
Type of outputs of sensor/device providing the input signal
for application function
S## terminals to be connected
Dynamization
Signal interlock monitoring
Synchronization:
Synchronized terminals
S12 synchronized with S13
S22 synchronized with S23
S32 synchronized with S33
S42 synchronized with S43
S52 synchronized with S53
S62 synchronized with S63
68
Value/Description
Monitoring of proximity switches
Two PNP outputs
S12 and S13 for sensor/device A
S22 and S23 for sensor/device B
S32 and S33 for sensor/device C
S42 and S43 for sensor/device D
S52 and S53 for sensor/device E
S62 and S63 for sensor/device F
If less than 6 safety-related inputs are used, the terminals
S#1, S#2 and S#3 of the unused safety-related inputs
must be bridged (example: sensor/device F not
connected: S61, S62 and S63 bridged).
Do not configure a start function with startup test if less
than 6 safety-related inputs are used.
No
Between terminals S12 and S13
Between terminals S22 and S23
Between terminals S32 and S33
Between terminals S42 and S43
Between terminals S52 and S53
Between terminals S62 and S63
Synchronization time
S12 and S213have to be activated within 0.5 s.
S22 and S23 have to be activated within 0.5 s.
S32 and S33 have to be activated within 0.5 s.
S42 and S43 have to be activated within 0.5 s.
S52 and S53 have to be activated within 0.5 s.
S62 and S63 have to be activated within 0.5 s.
HR9Z-B2200 8/2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hr6s-dn1cHr6s-dn1p

Table of Contents