Two Points / Double Pump Control - Bosch rexroth Sytronix FcP 5020 Quick Start Manual

Frequency-controlled pump drive system
Hide thumbs Also See for rexroth Sytronix FcP 5020:
Table of Contents

Advertisement

Bosch Rexroth AG
Block Diagram of Main Functions

7.9.3 Two Points / Double Pump Control

Code
Name
F2.40 Relay 1 output
F2.41 Extension relay output
Pump function configura-
F4.03
tion word
Maximum flow command
F4.24
limit
Two points / double pump
F4.28
selection
F4.29 Pump logic selection
F4.30 Pump Vg1
F4.31 Pump Vg2
Upper pressure difference
F4.32
switching threshold
Lower pressure difference
F4.33
switching threshold
Speed switching threshold
F4.34
adjustment
F4.38 Effective Pump Vg
Tab. 7-16: Parameter list of two points / double pump control
Choose different control mode and logic according to the type of pump by
F4.28.
For two points pump F4.30 (Vg1) reference the maximal displacement, and
F4.31 (Vg2) represents the smaller displacement. For double pump F4.30 (Vg1)
reference the main pump, and F4.31 (Vg2) is equal to the displacement of addi-
tional pump.
According to the pressure feedback, actual speed, F4.32, F4.33 and F4.34, the
pump switching logic will be calculated and carried out via the relay output,
once the output has been set, see F2.40, F2.41.
38/83
Setting range
0: No function assigned from ASF
1: Converter warning
2: Two points / double pump control
0...63
Bit0: Pump power limit
Bit1: Pump thermal protection
Bit2: Switch master to slave
Bit3: Two points / double pump
Bit4: Pressure drop / overshoot
compensation
Bit5: Activating myCro
[F4.23]...5,000 rpm
0: Two points pump
1: Double pump
0: Positive
1: Negative
0...1,000 ccm
0...1,000 ccm
0.0...350.0 bar
0.0...350.0 bar
0.1...1.0
0...1,000 ccm
Default
Min.
0
-
0
-
0
-
3,000
1
0
-
0
-
0
1
0
1
15.0
0.1
10.0
0.1
0.9
0.1
0
1
DOK-RCON03-FCP5020****-QU04-EN-P
FcP 5020
Attri.
Run
Run
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Read