Digital And Relay Output - Bosch rexroth Sytronix FcP 5020 Quick Start Manual

Frequency-controlled pump drive system
Hide thumbs Also See for rexroth Sytronix FcP 5020:
Table of Contents

Advertisement

Bosch Rexroth AG
Electric Connection

6.6 Digital and Relay Output

Code
Name
F2.36 DO1 output
F2.37 EDO output
F2.38 EDO2 output
F2.40 Relay 1 output
F2.41 Extension relay output
Tab. 6-7: Parameter list of digital and relay output
The FcP 5020 default setting of DO1 is ''1'', i.e. the frequency converter warning.
Meanwhile the default setting of relay and EDO / EDO2 when connected to ASF
are both ''0'', which means the function of relay and EDO / EDO2 is assigned by
EFC firmware.
The EFC parameter E2.15 has been set to ''14'' (frequency converter error) by
ASF as FcP default setting. For more EFC parameter changed as FcP default set-
ting, please refer to
tion" on page
74.
18/83
0: No function assigned from ASF
1: Converter warning
2: Green CytroPac flashing LED
3: Red CytroPac flashing LED
4: Oxygen too high (for myCro)
5: Pressure too low (for myCro)
0: No function assigned from ASF
1: Converter warning
2: Green CytroPac flashing LED
3: Red CytroPac flashing LED
4: Oxygen too high (for myCro)
5: Pressure too low (for myCro)
6: Degas/gas valve control (for my-
Cro)
0: No function assigned from ASF
1: Converter warning
2: Two points / double pump control
chapter 8.6 "Auto-modified EFC Parameters in FcP Initializa-
Setting Range
DOK-RCON03-FCP5020****-QU04-EN-P
FcP 5020
Default
Min.
Attri.
1
-
Run
0
-
Run
0
-
Run
0
-
Run
0
-
Run