90
Spindles - Select spindle Sx - Enter speed, e.g. 100, and position, e.g. 0 deg.
Softkey Position - Softkey Lock - Monitor the setup to see whether hydraulic
fluid flows out.
18.
Due to different requirements and/or specifications of the
respective manufacturers, be sure to review the respective
manufacturer's documentation!
Check and potentially replace O-rings or other seals on the clamping devices.
O-rings and other seals on the clamping devices prevent that chips or cooling
lubricant penetrate into the hydraulic circuit or even into the mechanical
components of the respective assemblies where they can cause significant
damage. In any case, make sure that the seals recommended by the
manufacturer are used or installed during maintenance or repair work.
Maintenance Summary - 4.000 Operating hours