Requirement
Procedure
36
Before removing the cover, shut off the power supply to the transmitter to prevent
irradiation by the laser beam. For certain maintenance activities, the cover must be
removed from the transmitter. Only use the supplied special tool to remove the
cover for maintenance. A face wrench is supplied.
Required accessories and tools
-
Face wrench (supplied)
-
Cleaning tool
-
Solvent-containing cleaner
-
Canned purified compressed air
-
Swabs
If the cover of the transmitter unit was removed, the power supply
must not be switched on again, as in the open state hazardous class
3R laser radiation may be emitted.
Always clean one unit at a time to avoid mixing up the covers.
1.
Risk of harmful laser exposure (Class 3R) at the
transmitter's laser output opening.
Danger
Turn off power supply.
Perform maintenance according to manufacturer's instructions.