Maintenance Summary - 4.000 Operating hours
Maintenance Instructions
R200
LR1702.10181 - 05.06.2019
4.
Example: Encoder wheel Heidenhain ERM
Clean encoder wheels. Do not use any metal tools or objects for cleaning.
To ensure optimum data exchange between the encoder and the encoder
wheel, the encoder wheel must be cleaned regularly. Ensure absolute
cleanliness, so that the cleaning does not lead to additional contamination of
the encoder wheel or the encoder.
5. Check the tightness of the hydraulic accessory units. Check the aligning and
indexing units, solid or open-center cylinders for leaks.
6.
Example: Cooling lubricant rotary distributor (e.g., from Hydronic)
Check cooling lubricant distributor rotary distributor. Detach the cooling
lubricant rotary distributor and check that cooling lubricant flows out. Cooling
lubricant should escape from the rotary distributor when the machine and
cooling lubricant pump are switched on and the work area door is closed.
87