Maintenance Summary - 4.000 Operating hours
Maintenance Instructions
R200
LR1702.10181 - 05.06.2019
10. Check O-ring (5), replace if necessary. To check the O-ring (5), loosen the
screws (7) of the guide ring (2) and remove the guide ring (2) from the spindle.
Check O-ring, replace if necessary. If necessary, insert a new O-ring, grease,
and tighten the screws (7) slightly.
11. Check Glyd® ring (4), replace if necessary. To replace the Glyd® ring, lift it
carefully with a small screwdriver in the recess, taking care not to damage the
recess, and remove the Glyd® ring. Grease the new Glyd® ring and insert it
into the recess. Carefully precalibrate the Glyd® ring in the guide ring (2), using
the cooling lubricant and stopper unit (1). After a few minutes, remove the
guide ring (2) from the cooling lubricant and stopper unit (1).
12. Reinstall the cooling lubricant and stopper unit (1), securing it with the screws
(6). Then position the cooling lubricant and stopper unit (1) according to the
setting value. Use the two-flat (Y) for the adjustment. Then tighten the screws
(X).
13. Insert guide ring (2) into the spindle from the front, position it according to the
setting value and retighten the screws (7).
14. Screw in and tighten the bar stop (3).
15. Reattach the cooling lubricant rotary distributor.
16.
Do not reinstall any existing screen in the draining outlet of the
clamping cylinder. The screen may clog to the extent that the
cooling lubricant dams up so that it can enter the hydraulic fluid
circuit via the clamping cylinder.
Example: Cooling lubricant outlet on the clamping cylinder
X
Screws on the acrylic glass cover
Check the cooling lubricant drain on the clamping cylinder. Check that the drain
is free and contains no chips. Loosen screws (X) and remove acrylic glass
cover on the cooling lubricant drain of the clamping cylinder. Remove chips or
other impurities and ensure that the cooling lubricant can drain off.
17. Check the aligning and indexing units for function and tightness. By repeated
pressing of the Softkey Lock/Unlock in Softkey Operate Units . Softkey
89