Maintenance Summary - 4.000 Operating hours
Maintenance Instructions
R200
LR1702.10181 - 05.06.2019
Hydraulic fluid filter R200
e
Accumulator drain valve
X
Hydraulic fluid filter
Y
Filter bowl
Replace the filters (Z) of the hydraulic fluid filters (X). A different number of
hydraulic fluid filters (X) may be installed, depending on the version. Unscrew
filter bowl (Y), remove contaminated hydraulic fluid (oil sump) and used filter
(Z) from the filter bowl (Y) and dispose of them according to environmental
regulations.
6.
Only filters with retained particle sizes described in the fluid
plans must be used.
Example: Filter (Z)
Clean filter bowl (Y) and insert a new filter (Z). Reinstall the filter bowl (Y) and
tighten by hand until it stops. Then back off the filter bowl (Y) 1/8 turn.
7. To fill in new hydraulic fluid, use a pump with a min. 10 µm micro filter that is
exclusively used for hydraulic fluid.
8. Fill in the prescribed amount of new hydraulic fluid.