SPN
Component / Location
523550
Terminal 50
523550
ECU internal error
523561
Begin of injection period
523562
Begin of injection period
523563
Begin of injection period
523564
Begin of injection period
523565
Begin of injection period
523566
Begin of injection period
523567
Begin of injection period
523568
Begin of injection period
523600
ECU internal error
523601
ECU internal error
523602
Fan speed
523604
CAN message
523605
CAN message
523606
CAN message
523607
CAN message
523608
CAN message
523609
CAN message
523610
CAN message
523611
CAN message
523612
ECU internal hardware monitoring
523612
ECU internal hardware monitoring
523612
ECU internal hardware monitoring
523612
ECU internal hardware monitoring
523612
ECU internal hardware monitoring
523613
Rail pressure
523613
Rail pressure
523613
Rail pressure
523613
Rail pressure
523613
Rail pressure
523613
Rail pressure
523615
Metering unit valve
523615
Metering unit valve
523615
Metering unit valve
523615
Metering unit valve
523617
ECU internal error
-
Customer-specific sensor
-
Customer specific temperature
Description (Error location)
Engine start switch hangs
Time processing unit (TPU) defective
Outside target range or missing (cylinder 1)
Outside target range or missing (cylinder 2)
Outside target range or missing (cylinder 3)
Outside target range or missing (cylinder 4)
Outside target range or missing (cylinder 5)
Outside target range or missing (cylinder 6)
Outside target range or missing (cylinder 7)
Outside target range or missing (cylinder 8)
Serial communication interface defective
Wrong voltage of internal 5V reference source 3
Aove target range with system reaction
Missing (message "RxEngTemp" = engine temperature)
Missing (message "TSC1-AE")
Missing (message "TSC1-AR")
Missing (message "TSC1-DE")
Missing (message "TSC1-DR")
Missing (message "TSC1-PE")
Missing (message "TSC1-VE")
Missing (message "TSC1-VR")
A recovery occured which is stored as protected
A recovery occured which is not stored
A recovery occured which is visible in the error memory
Overvoltage
Undervoltage
Positive deviation (speed dependent) outside target range
Positive deviation (flow dependent) outside target range ( => Leakage!)
Negative deviation (flow dependent) outside target range
Negative deviation (speed dependent) outside target range
Pressure above target range
Implausible (leakage, injector needle blocked in open position)
Flow rate outside target range
Not connected or output disabled
Short circuit to Ubatt
Short circuit to ground
Communication with chip CJ940 disturbed
Cable break or short circuit (sensor 1)
Outside target range with system reaction (tempereature 1)
7 - Repair
FMI
11, 12
2, 11
2
2
2
2
2
2
2
2
11, 12
3, 4, 11
2, 11
11, 12
11, 12
11, 12
11, 12
11, 12
11, 12
11, 12
11, 12
11, 14
11, 14
11, 14
3, 11
4, 11
0, 11
0 , 11
0, 11
1, 11
0, 11
2, 11
3, 4, 11
5, 11, 12
11, 12
11, 12
11, 12
2, 3, 4, 11
2, 11
199