Electrical Connections

IntelliTrack Potentiometer Connection

When connecting the IntelliTrack sprayer to the tractor, it is important to
set up the front potentiometer on the drawbar correctly. The
potentiometer must be connected to the tractor with the two supplied
chains.
μ
ATTENTION! To ensure high precision, the chains must be parallel
and horizontal.
Procedure when connecting the sprayer to the tractor:
1. Connect the sprayer.
2. Drive forward to ensure the sprayer follows the tractor in a straight
line.
3. Connect the two chains for the potentiometer, while ensuring the transverse potentiometer bar is perpendicular to
the drawbar. Tighten the chains, so that the torsion levers (A) are vertical.
4. Go to menu 4.7 in the controller unit and check if the potentiometer reading F is 2.50 Volt, i.e. in the centre position.
5. If the reading F is not correct, adjust the chain connection until F = 2.50 Volt. Allowable deviation is ±0.05 Volt.

Power Supply

Power requirement is 12 V DC. Always note polarity! For proper function
of the electric equipment, the wires must have the following
recommended cross sectional areas and correct fuses to ensure a
sufficient power supply.
The delivered power connectors follows the standard of most modern
tractors. If you have a tractor with another power connector, it is
necessary to disassemble the connector and fit it to the actual tractor
connector.
The number and the type of connectors may vary on the specific
sprayer, depending on its equipment.
Cigar connector, 1-pin
Spray control unit requires:
Wire 2.5 mm
Hydraulic control unit requires:
Wire 4.0 mm
JobCom connector, 3-pin
The unit requires:
Wire 6.0 mm
ISOBUS connector, 9-pin
2
. Fuse 10 amps.
2
. Fuse 16 amps.
2
. Fuse 25 amps.
4 - Sprayer Setup
Traffic light connector, 7-pin
Working light connector, 2-pin
The unit requires:
2
Wire 10.0 mm
. Fuse 30 amps.
Power and data connector, 13-pin
For HC 6500 controller.