Liquid System; Pump; Valves And Symbols - Hardi NAVIGATOR DELTA FORCE Instruction Book

Hide thumbs Also See for NAVIGATOR DELTA FORCE:
Table of Contents

Advertisement

Liquid System

Pump

Diaphragm pump with 6 diaphragms, model 363 or 364 or 464.
Standard = 540 rpm (6 splines shaft). Optional = 1000 rpm (21 splines
shaft). The design of the diaphragm pump is simple, with easily
accessible diaphragms and valves, which ensure that liquid does not
contact the vital parts of the pump.
Pump model 363 is shown on the picture.

Valves and Symbols

The possible functions of valves are distinguished by coloured identification on the function labels. The modular valve
system facilitates the addition of optional extras on both pressure side and suction side. A function is activated by turning
the handle towards the desired function.
μ
ATTENTION! Only the functions used should be open - always close remaining valves.
μ
ATTENTION! If a valve is too tight to operate - or to loose (= liquid leakage) - the valve needs to be serviced. Please see
"Adjustment of 3-Way Valve" on page 133 for further information.
Pressure SmartValve (Green Symbols)
This valve is to select which function the pressurized liquid from the
pump will be routed to.
The active function is indicated by the indicator. The handle is turned so
the indicator points to the label for required function. If the handle is
turned to a position without label (unused function), the valve is closed.
Main tank
IInternal tank cleaning
(Rinsing nozzles)
(optional)
Suction Valve (Blue symbols)
This valve is to select suction from main tank or from the rinsing tank.
The handle is turned so the label for required function is directed to the
indicator. If the handle is turned to vertical position (indicator not
pointing at a label), the valve is closed.
Main tank
Spraying
Pressure draining (optional)
or TurboFiller (optional)
Rinsing tank (optional)
3 - Description