Hours Service - Check/Adjust Drawbar (Fixed High Drawbar Only); 100 Hours Service - Retightening The Spray Boom; 250 Hours Service - Hydraulic Circuit; 250 Hours Service - Hoses And Tubes - Hardi NAVIGATOR DELTA FORCE Instruction Book

Hide thumbs Also See for NAVIGATOR DELTA FORCE:
Table of Contents

Advertisement

6 - Maintenance

100 Hours Service - Check/Adjust Drawbar (Fixed High Drawbar only)

If too many movements occur sideways, the drawbar must be adjusted.
1. Loosen counternuts (B).
2. Regulate on the turnbuckles (A) on each side to adjust and center
the drawbar.
3. Tighten counternuts (B).

100 Hours Service - Retightening the Spray Boom

Due to several movements of the spray boom from driving in the field with an unfolded boom, you must retighten all bolted
connections on the boom centre and boom wings.
Where you find bolts with Nord-Lock washers, please tighten with the
following torques.
Bolt size
Torque (Nm)
M10
50
M12
85
M14
136
M16
208
M18
291
M20
408
M22
557
M24
703
M27
1028
M30
1401

250 Hours Service - Hydraulic Circuit

Check the hydraulic circuit for leaks and repair, if needed.
Refill nitrogen accumulators for:
• ParaLift suspension (if fitted)
• Wheel axle suspension (if fitted)
• Yaw suspension (if fitted)
±
WARNING! Hoses for boom lifting device must be changed after every 5 years of use.
±
WARNING! Nitrogen accumulators may contain oil under pressure.

250 Hours Service - Hoses and Tubes

Check all hoses and tubes for possible damage and proper attachment. Replace damaged hoses or tubes.