10 Hours Service - Cyclonefilter; 10 Hours Service - Inline Filter - Hardi NAVIGATOR DELTA FORCE Instruction Book

Hide thumbs Also See for NAVIGATOR DELTA FORCE:
Table of Contents

Advertisement

10 Hours Service - CycloneFilter

Servicing the filter
1. Turn the pressure valve towards the unused function or to tank
cleaning nozzles.
2. Unscrew the filter lid (A).
3. Lift lid and filter (B) from the housing.
4. Turn the two locks (C) outwards to unlock the filter from the lid.
5. Separate filter from the integrated filter guide in the lid and clean
the filter.
To reassemble
1. Grease the two O-rings on the lid/filter guide. Due to small space
at lid, use for example a brush to apply the grease.
2. Mount the filter onto the recess (which may not be greased) in the
lid/filter guide.
3. Turn the two locks (C) inwards to lock the filter to the lid.
4. Place the filter/filter lid into the housing and screw the lid, until it hits the stop.
±
WARNING! Always wear protective clothing and gloves, before servicing the filter!
DANGER! The pressure valve must always be turned to the unused function or to tank cleaning nozzles, before
opening the CycloneFilter! If not, the spraying liquid can hit you, when opening the filter, and the main tank content
will drain away!

10 Hours Service - InLine Filter

If the boom is equipped with In-Line Filters, unscrew the filter bowl to
inspect and clean the filter. When reassembling, the O-ring should be
greased.
Alternative filter meshes are available. See section "Technical
specifications" - Filters and nozzles.
±
WARNING! Be careful not to splash out liquid, when unscrewing
the filter bowl.
±
WARNING! Always wear protective clothing and gloves, before
servicing the filter!
10 Hours Service - Nozzle Filters
The filters are located inside the nozzles.
Check the filter condition and clean the filter.
6 - Maintenance