5 - Operation

Operating the Control Units While Spraying

The control units in the tractor control the following functions in the field:
Power ON/OFF/status, LED light. The light must be ON.
Automatic spray pressure regulation.
The regulation valve controls the main spray pressure. This is default
selection when the controller is powered ON, and it should remain
here during normal spraying.
Manual spray pressure regulation.
During normal spraying, these regulations should not be used, as the
regulation valve does this automatically.
Optional function, A or B.
If extra equipment is fitted, it can be controlled from here.
The IntelliTrack function is used, when making turns in the field,
ensuring
- a small turning radius
- a better stability when turning
- that the spray boom is perpendicular to the crop rows.
Press "auto" for automatic adjustment of the sprayer.
Press left or right arrow key to manually adjust the sprayer tracking
Press double arrow key to lock the sprayer tracking (the hydraulics will
adjust the sprayer to its centre position, and a mechanical lock will be
activated at the rear).
A. Power ON/OFF/status LED light. The light must be ON.
B. Section valves for spray boom. Turns separate spray sections ON or
OFF. Lever up is OFF, lever down is ON.
C. Main valve ON/OFF.
÷
NOTE! Check the current volume application rate on the display,
or see the instruction book for the spray controller for more
information.