4 - Sprayer setup

Electrical connections

Power supply

Power requirement is 12V DC. Note polarity! The wires must have a
cross sectional area of at least 4.0 mm to ensure a sufficient power
supply. For the operating unit the tractor circuit should have an 8
Amp fuse. The delivered power connector follows the standard of
most newer tractors. If having a tractor with another power connec-
tor it is necessary to disassemble connector and fit it to the actual
tractor connector.

Control boxes

Control boxes are fitted in the tractor cabin at a convenient place.

Installation of control box - EVC control unit

Find a suitable place in the tractor's cabin. Best recommended pla-
cement is to the right of the driver seat and in combination with the
Hydraulics control unit. It should be secured from movement.

Installation of control unit brackets

The supplied tractor pillar bracket (A) has a hole spacing of 100 and
120 mm. Check tractor instructions manual for information regar-
ding attachment points.
Three tubes (B) are supplied. One, two or all 3 may be used. They can
be bent and shortened. A spacer (C) is also supplied to allow further
attachment possibilities. Find the best solution for your tractor or
vehicle.
Tube (B) plate is staggered so if correctly orientated, all boxes will
line up.