After first use - Bolts and nuts boom
• Check that all bolts and nuts are properly tighten and re-tighten if necessary using suitable tool. See page page 53 for
correct torque settings.

10 hours service - In-Line filter (not PrimeFlow)

If the boom is equipped with In-Line Filters, unscrew the filter bowl to
inspect and clean the filter. When reassembling, the O-ring should be
greased and if damaged replaced.
Alternative filter meshes are available. See section on Technical
specifications - Filters and nozzles.
±
WARNING! Be careful not to splash out liquid when unscrewing
the filter bowl.
±
WARNING! Always wear protective clothing and gloves before
opening the filter!
10 hours service - Nozzle filters
Check and clean.

10 hours service - Spraying circuit

Fill with clean water, operate all functions and check for leaks using higher spray pressure than normal. Check nozzle spray
patterns visually using clean water.

50 hours service - Lubricate boom and centre

Lubrication points on the boom and centre needs attention every 50 working hours to work correctly.parts. see "Paralift
lubrication & oiling plan" on page 51 and "Lubrication" on page 49

50 hours service - Bolts and nuts boom

-Check that all bolts and nuts are properly tighten and re-tighten if necessary using suitable tool. Large bolt and nuts should
be really tight, it is recommended to use a spanner with a 1-metre extension bar.

50 hours service - Spring break away

Check the tension of the break-away spring see "Breakaway section adjustment" on page 64