Installing/Removing the Rack Model into the Rack
Ê Secure the end of the telescopic rails with the corresponding assembly
brackets with two screws M4x8 each or the telescopic rails without brackets
with two screws M5x10 each (1 and 2) at the support uprights and/or at the
support bracket in the rack (figure 6 on page 35).
Note with the fact that two mounting springs each are used in the appro-
priate openings of the support uprights and/or the support bracket (see
figure 5 on page 34).
Ê Adjust if necessary the length of the telescopic rails.
Ê Mount the PRIMECENTER Rack cable management as described in the
Technical Manual of the PRIMECENTER Rack.
Ê Mount the server (see section "Installing the Server" on page 46).
Ê Route the cables with the inserted server as described in the technical
manual of the PRIMECENTER Rack.
4.4.2

Mounting into the DataCenter Rack

For mounting the server into the DataCenter Rack the following parts are
necessary:
– support bracket
– two telescopic rails (assembled)
– possibly assembly bracket HL (are punched onto the bracket)
– two or eight mounting springs/plugwashers (figure 5 on page 34)
I
To ensure the frontal assembling of the telescopic rails to the support
bracket and/or to the support uprights assembly brackets are supplied.
If none assembly brackets are supplied the telescopic rails are frontally
fastened on the support bracket and/or on the support uprights.
I
General information are provided in the Technical Manual for the
DataCenter Rack (see also "Related Publications" on page 107).
Ê For mounting the telescopic rails without assembly brackets see section
"Mounting into the PRIMECENTER Rack" on page 32.