Hot-plug PCI Boards
8.5

Replacing hot-plug PCI Boards

V
CAUTION!
The actions described in this section may only be performed by
personnel with the appropriate technical training. Any unauthorized
openings and improper repairs could expose the user to risks (electric
shock, fire hazards) and could also damage the equipment.
Please observe the safety information in chapter "Important Notes" on
page 13.
In order to replace a hot-plug PCI board, the left side cover (floorstand
model) or the housing cover (rack model) must be removed as the slots
are not directly accessible (see section "Opening/Closing the Housing"
on page 97).
The failure of a hot-plug PCI board is notified for the corresponding slot on the
card guide on the inside of the server (see table 3 on page 62 and figure 39 on
page 95).
Ê You should read the accompanying documentation supplied with the board
beforehand.
I
Only PCI boards of the same type and with the same settings may be
exchanged. If the boards do not match, the new board will not be
commissioned.
Ê Remove the left side cover (floorstand model) or the housing cover (rack
model) (see section "Opening/Closing the Housing" on page 97).
Ê If necessary, start the PCI hot-plug software (PCI Card HotReplace). You will
find operating instructions in the file "README for the PCI Hot Plug
Software V3.0" on the ServerStart CD.
Ê Deactivate the board using the relevant PCI hot-plug software or by pressing
the button (a) (see figure 39 on page 95).
The power indicator for the hot-plug PCI slot (b) (see figure 39 on page 95)
flashes green (see table 3 on page 62). The slot is in the disable sequence.
Ê Wait until the power indicator changes its status (not lighting). The slot is now
powered off.