Hot-plug/hot-swap Components
V
CAUTION!
Check the direction of rotation of the fan wheel before installing a fan
housing.
The direction of the air flow is indicated on the fan by an arrow.
The air flow must be in the direction of (a) (figure 38 on page 92).
Ê Route the connection cable in the new fan cartridge as it was previously
routed in the fan cartridge you removed.
Ê Push the new fan cartridge into the empty mounting location. The retaining
clip on the fan cartridge clicks audibly into place.
Ê Connect the connection cable to the fan cartridge.
Ê Press the S1 switch on the fan board (see figure 37 on page 91). The switch
signals to Server Management that a system fan has been replaced.
The new system fan is tested by Server Management. The relevant LED
then lights green on the fan board (fan is working) or orange (fan is not
working).
Ê Replace the left side cover (floorstand model) or the housing cover (rack
model) (see section "Opening/Closing the Housing" on page 97).