Installation and Configuration
N O T E : Outputs must be connected as all sourcing or all sinking.
J106
OUTPUT SWITCHES
EACH OUTPUT 50 mA MAXIMUM
1
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
2
Figure 2-24:
J106
OUTPUT SWITCHES
EACH OUTPUT 50 mA MAXIMUM
1
2
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
Figure 2-25:
50
OPTOCOM
J106-15
1
OPTOOUT0
J106-7
OPTOOUT1
J106-8
OPTOOUT2
J106-9
OPTOOUT3
J106-16
+
LOAD
-
Outputs Connected in Current Sourcing Mode (J106)
+
LOAD
-
OPTOOUT0
J106-7
OPTOOUT1
J106-8
OPTOOUT2
J106-9
1
OPTOOUT3
J106-16
OPTOCOM
J106-15
Outputs Connected in Current Sinking Mode (J106)
Chapter 2
Ensemble LAB Hardware Manual
+
LOAD
-
+
LOAD
-
5-24 VDC
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
www.aerotech.com
2
+
-
5-24 VDC
+
-
2