H3C SecPath M9000-AI Manual page 33

Table of Contents

Advertisement

The gateway SEM provides LEDs for modules installed on the gateway to indicate their operating
status.
Table 2-7
and
gateway LEDs, see H3C SecPath M9000-AI Multiservice Security Gateway Installation Guide.
Table 2-7 M9000-AI-E8 SEM LED description
LED
Status
OK
On
Fan tray status
LED (FAN)
Off
Off
OK
Power supply
On
status LED
Off
(PWR)
Off
RUN
Flashing (4
Hz)
Flashing
Slot status LED
(0.5 Hz)
(SLOT)
Flashing
(0.5 Hz)
On
Off
On
Active/standby
status LED
Off
(ACTIVE)
Table 2-8 M9000-AI-E16 SEM LED description
LED
Status
Steady green
Fan tray status LED
Steady red
(FAN)
Off
Power supply
Steady green
t t
LED (PWR)
Table 2-8
describe the LEDs on the SEM. For more information about
FAIL
Off
On
Off
FAIL
Off
On
Off
ALM
On
Off
Flashing
(0.25 Hz)
On
Off
Description
All the fan trays are operating correctly.
A fan tray is faulty, or no fan tray is present.
No power is present on the gateway.
All the installed power supplies are operating correctly.
32
Description
All fan trays are operating correctly.
A fan tray is faulty or no fan trays are present.
The gateway is not powered on.
All power supplies are operating correctly.
One or more power supplies are faulty.
The gateway is not powered on.
The module is loading software.
If the LED stays in this status, the software version of the
gateway does not match that of the module.
The module is operating correctly.
The temperature of the module has reached the
high-temperature warning threshold or dropped below the
low-temperature threshold.
The module is starting up or faulty.
The module is not present.
The SEM is operating in active mode.
The SEM is operating in standby mode.
The SEM is faulty. Examine also the status LED for
the SEM to determine whether a fault has occurred.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Secpath m9000-ai-e8Secpath m9000-ai-e16