H3C SR6602-I AI Series Hardware Information
H3C SR6602-I AI Series Hardware Information

H3C SR6602-I AI Series Hardware Information

Ict converged gateways
Hide thumbs Also See for SR6602-I AI Series:

Advertisement

Quick Links

H3C SR6602-I[IE] AI Series
ICT Converged Gateways
Hardware Information and Specifications
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 5W100-20200923

Advertisement

Table of Contents
loading

Summary of Contents for H3C SR6602-I AI Series

  • Page 1 H3C SR6602-I[IE] AI Series ICT Converged Gateways Hardware Information and Specifications New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 5W100-20200923...
  • Page 2 The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3 Preface This document describes hardware information for the H3C SR6602-I[IE] AI series ICT converged gateways, including views and technical specifications of the chassis and removable components, LEDs, slot arrangement, and interface numbering. This preface includes the following topics about the documentation: •...
  • Page 4 Convention Description Folder. Symbols Convention Description An alert that calls attention to important information that if not understood or followed WARNING! can result in personal injury. An alert that calls attention to important information that if not understood or followed CAUTION: can result in data loss, data corruption, or damage to hardware or software.
  • Page 5 It is normal that the port numbers, sample output, screenshots, and other information in the examples differ from what you have on your device. Documentation feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments.
  • Page 6: Table Of Contents

    Contents 1 Chassis views and technical specifications ·············································· 1-1 Chassis views ················································································································································· 1-1 SR6602-I/SR6602-IE ······························································································································ 1-1 Power button ··········································································································································· 1-3 Technical specifications ·································································································································· 1-4 SR6602-I/SR6602-IE technical specifications························································································· 1-4 Weights, dimensions, and power consumptions ····················································································· 1-5 Heat dissipation ······································································································································· 1-7...
  • Page 7: Chassis Views And Technical Specifications

    Chassis views and technical specifications SR6602-I AI series is a set of new ICT converged gateways developed by H3C for enterprise networks and AI scenarios. It uses an open architecture and innovative mechanical and electrical designs, delivers IT and CT converged solutions, and drives business innovations and rapid delivery.
  • Page 8 Figure1-2 Rear panel (1) Riser module slot (2) Fan tray slot 1 (3) Fan tray slot 2 (4) Fan tray slot 3 (reserved) (5) Power supply slot 2 (6) Power supply slot 1...
  • Page 9: Power Button

    Figure1-3 System board (1) BIOS jumper (2) System battery (3) Fan tray bay (4) Riser connector (5) DDR4 memory slot 4 (6) DDR4 memory slot 3 (7) SATA connector (8) M.2 drive connector (KEY M) (9) DDR4 memory slot 1 (10) DDR4 memory slot 2 Power button WARNING!
  • Page 10: Technical Specifications

    • For service continuity, avoid touching the power button accidentally or mistakenly during device operation. • If a virtual machine cannot be shut down gracefully, log in to it, terminate the running processes, and then shut down it. The power button is used to power on or power off the Comware system and virtual machines created on the Comware system.
  • Page 11: Weights, Dimensions, And Power Consumptions

    Weights, dimensions, and power consumptions Chassis The device uses modular design. Its weight includes the chassis (including mounting brackets and filler panels) and its internal and external removable components. The total weight varies by the numbers and types of the removable components. Table1-2 Chassis weights and dimensions Weight (chassis only, Dimensions (H ×...
  • Page 12 Power supplies Table1-4 Power supply weights and dimensions Power supply model Net weight Dimensions (H × W × D) PSR250-12A1 0.6 kg (1.32 lb) 40 × 51 × 221 mm (1.57 × 2.01 × 8.70 in) PSR450-12A1 0.65 kg (1.43 lb) 40 ×...
  • Page 13: Heat Dissipation

    Table1-10 Memory weights and power consumptions Memory model Net weight Max power consumption DDR4-2666-32G-2Rx4-R 0.02 kg (0.04 lb) 2.5 W Table1-11 M.2 SSD drive weights, dimensions, and power consumptions Max power M.2 SSD drive model Net weight Form factor consumption SSD-480G-SATA-M.2 0.015 kg (0.03 lb) SFF (2.5 inch)
  • Page 14 Contents 2 Removable component views and technical specifications ······················ 2-1 Removable component views ························································································································· 2-1 FIP modules ············································································································································ 2-1 AC power supplies ·································································································································· 2-2 DC power supplies ·································································································································· 2-3 High voltage DC supplies ························································································································ 2-3 Fan trays ················································································································································· 2-4 Riser modules ········································································································································· 2-4 Storage controllers ··································································································································...
  • Page 15: Removable Component Views And Technical Specifications

    Removable component views and technical specifications Removable component views FIP modules Figure2-1 FIP-30 front panel (1) MIC-X interface module slot 1 (2) MIC-X interface module slot 2 (3) Latch (4) Ejector lever (5) Remove button/LED (6) 1000BASE-X-SFP Ethernet fiber ports 4 through 19 (7) 10GBASE-R-SFP+ Ethernet fiber ports 0 through 3...
  • Page 16: Ac Power Supplies

    AC power supplies PSR250-12A1 Figure2-2 PSR250-12A1 front panel (1) Latch (2) Power supply status LED (3) Handle (4) Power receptacle PSR450-12A1 Figure2-3 PSR450-12A1 front panel (1) Latch (2) Power supply status LED (3) Handle (4) Power receptacle...
  • Page 17: Dc Power Supplies

    DC power supplies Figure2-4 PSR450-12D front panel (1) Latch (2) Power supply status LED (3) Handle (4) Power receptacle High voltage DC supplies Figure2-5 PSR450-12AHD front panel (1) Latch (2) Power supply status LED (3) Handle (4) Power receptacle...
  • Page 18: Fan Trays

    Fan trays Figure2-6 FAN-80-1 front panel (1) Fan tray release button (2) Fan tray status LED Riser modules Figure2-7 Riser module view (1) PCIe slot (for a storage controller or GPU) (2) GPU power connector (3) GPU support bracket and screw (4) Cable tie (for GPU power cables)
  • Page 19: Storage Controllers

    NOTE: The GPU support bracket and four screws are shipped with the riser module. Three are used for installing the GPU support bracket and one is used for securing the storage controller or GPU to the riser module. Storage controllers Figure2-8 Storage controller view (1) Storage controller golden plating (2) Storage controller cable connector...
  • Page 20: Dimms

    (4) GPU power cable DIMMs Figure2-10 DIMM view (1) Notch of DIMM golden plating M.2 SSD drives Figure2-11 M.2 SSD drive view (1) Screw location of the M.2 SSD drive (2) Golden plating of the M.2 SSD drive (3) Screw for the M.2 SSD drive (shipped with the document bag for the chassis)
  • Page 21: Technical Specifications

    MIC-X interface module slots Hot swappable MIC-X interface modules The SR6602-I and SR6602-IE ICT converged devices support MIC-X interface modules. For more information about MIC-X interface modules, see H3C SR6602-I[IE] AI Series ICT Converged Gateways Interface Module Guide. Power supplies IMPORTANT: To ensure correct operation of the device when it is installed with a GPU, use two 450W power supplies to supply power to the device.
  • Page 22: Fan Trays

    High voltage DC power supplies Table2-4 High voltage DC power supply specifications Rated input voltage Maximum output Model Maximum power range current 100 VAC to 240 VAC @ AC input 450 W 50/60 Hz PSR450-12AHD High voltage 240 VDC to 380 VDC 3.5 A 450 W DC input...
  • Page 23: Riser Modules

    Riser modules Table2-8 Riser module specifications Model Installation slot Supported PCIe module • UN-GPU-P40-X RT-RISER-FHFL-X16 Slot 2 • UN-HBA-H460-B1 Storage controllers IMPORTANT: The device supports RAID only when two external SATA drives are installed in the device. Make sure the SATA drives are the same capacity. Redundant Array of Independent Disks (RAID) is a data storage virtualization technology that combines multiple physical disks into one logical drive group for performance improvement and data redundancy.
  • Page 24: Dimms

    Item Specifications Power connector DIMMs Table2-12 DIMM specifications Model Type RANK Capacity Data rate DDR4-2666-32G-2Rx4-R RDIMM Dual-rank 32 GB 2666 MHz M.2 SSD drives Table2-13 M.2 SSD drive specifications Model Capacity Port type Rate SSD-480G-SATA-M.2 480 GB SATA 6 Gbps 2-10...
  • Page 25 Contents 3 LEDs ········································································································ 3-1 Chassis LEDs·················································································································································· 3-1 FIP module LEDs ············································································································································ 3-3 MIC-X interface module LEDs ························································································································ 3-4 Power supply LEDs ········································································································································· 3-4 Fan tray LEDs ················································································································································· 3-6...
  • Page 26: Leds

    LEDs Chassis LEDs Figure 3-1 Chassis LEDs (1) 10GBASE-R-SFP+ Ethernet fiber port LEDs 6 through 19 (2) 10/100/1000BASE-T Ethernet copper port LEDs 20 through 31 (3) Power button/LED (4) Running status LED (RUN) (5) System alarm LED (ALM) (6) IRF LED (reserved) (7) Storage controller status LED (RAID) (8) 10GBASE-R-SFP+ Ethernet fiber port LEDs 4 and 5 (9) 10GBASE-R-SFP+ Ethernet fiber port LEDs 0 through 3...
  • Page 27 Status Description Mbps. No link is present on the port. A power cord is connected to the device or the Flashing red (8 Hz) power button is pressed to start up the Comware system. Flashing red (1 Hz) The BIOS is starting up. Flashing green (1 Hz) The BIOS has started and BootWare is starting up.
  • Page 28: Fip Module Leds

    FIP module LEDs Figure 3-2 FIP module LEDs (1) 10GBASE-R-SFP+ Ethernet fiber port LEDs 0 through 3 (2) 1000BASE-X-SFP Ethernet fiber port LEDs 4 through 19 (3) Remove button/LED Table 3-2 FIP module LED descriptions Status Description Steady green A 10 Gbps link is present on the port. Flashing green (3 Hz) The port is sending or receiving data at 10 Gbps.
  • Page 29: Mic-X Interface Module Leds

    MIC-X interface module LEDs For more information about MIC-X interface module LEDs, see H3C SR6602-I[IE] AI Series ICT Converged Gateways Interface Module Guide. Power supply LEDs Figure 3-3 PSR250-12A1 power supply LEDs (1) Power status LED Figure 3-4 PSR450-12A1 power supply LEDs...
  • Page 30 Figure 3-5 PSR450-12D power supply LEDs (1) Power status LED Figure 3-6 PSR450-12AHD power supply LEDs (1) Power status LED Table 3-3 Power supply LED description Status Description Steady green The power supply is operating correctly. The power supply has normal power input but has Flashing green not been installed in the device.
  • Page 31: Fan Tray Leds

    Status Description device. • The power supply is in input undervoltage protection state. No power is present. Fan tray LEDs Figure 3-7 FAN-80-1 fan tray LEDs (1) Fan tray status LED Table 3-4 Fan tray LED description LED status Description Steady green The fan tray is operating correctly.
  • Page 32 Contents 4 Slot arrangement and interface numbering ·············································· 4-1 Slot arrangement············································································································································· 4-1 Interface numbering ········································································································································ 4-1 Conventions ············································································································································ 4-1 Examples ················································································································································ 4-1...
  • Page 33 Slot arrangement and interface numbering Slot arrangement Table4-1 Slot arrangement on the device Slot arrangement : FIP module slot Interface numbering Conventions The interfaces (except the management Ethernet interface) on the router are numbered interface-type X/Y/Z. The management Ethernet interface number is M-GigabitEthernet 0/0/0. •...

This manual is also suitable for:

Sr6602-ie ai series

Table of Contents