Resolvers
Correct Connection Example
Resolver's 3F88L-CR0R2A Auxiliary Connection Cable (provided with the Cam Positioner Unit).
3F88L-CR0R2A Auxiliary Connection Cable
(One piece provided with Cam Positioner Unit)
Incorrect Connection Example
The resolver cable transmits signals that require precision at low voltage. In order to avoid receiving inductive
noise that could adversely affect these signals, it is recommended that resolver cables be wired as far as pos-
sible from other lines.
Keep in-panel wiring as far away as possible from control wires and power lines.
External wiring should be contained in a weak-current duct used exclusively for that purpose, and it should be
covered with a grounded metal plate.
Connector
To Cam Positioner Unit
Repeater terminal block
Connector
(((
3F88L-CR
C Extension Cable
Appendix B
Resolver
55