Memory Allocation
I/O clas-
Bit number
sifica-
Word
Bit
tion
Out
n
02
01
00
n+1
15 to 08 ---
07 00
28
Data item
EEPROM write
Turn this bit from OFF to ON to write the origin adjustment value to the
EEPROM in the Cam Positioner Unit after the origin adjustment has
been determined. Because there is a limit to the number of times that
data can be written to EEPROM (approx. 10,000 times), it is recom-
mended that this bit be turned ON only once, after the final determina-
tion has been made.
Bit 05 of word n + 8 will be ON when data is written to the EEPROM.
Origin adjustment
To execute the origin adjustment, turn this flag from OFF to ON. When
the origin adjustment has been completed, bit 05 of word n + 8 will turn
ON.
When this flag (bit 01 of word n) is turned from OFF to ON, the origin
adjustment value is written to the RAM in the Cam Positioner Unit.
After the final origin adjustment determination, turn bit 02 of word n
from OFF to ON to write the value to EEPROM.
Operation
When this flag turns ON, the bank in word n + 1 begins operation. Dur-
ing operation, the RUN indicator on the Data Setting Console will light
and cam outputs will turn ON and OFF according to the data that is set.
When this flag turns OFF, operation will stop.
Not used. Set to "0."
Bank number
The number of the bank to be executed (00 to 08) is set in two digits
BCD. If "00" is set, there are no cam outputs. Make the bank number
setting while the Operation Flag (bit 00 of word n) is turned OFF. If the
Operation Flag is ON, then turn it OFF and back ON when changing
the bank number setting. Without doing this, the bank number cannot
be changed.
Data contents