Omron SYSMAC C200H-CP114 Operation Manual page 67

Hide thumbs Also See for SYSMAC C200H-CP114:
Table of Contents

Advertisement

Resolvers
Resolver Mounting Dimensions
3F88L-RS17/RS17T (Flange Mounting)
Recommended mounting holes
Mounting
Note The flange can withstand a force of 25 kgf (245 N) on the center of the resolver.
3F88L-RS15/RS15W (Flange Mounting)
Recommended mounting holes
Mounting
Mounting hooks
(External diameter: φ:67)
Linking the Resolver Directly to the Mechanical System
Using the coupling (3F88L-RL6/RL10) provided with the resolver, link the rotational system's axle to the
resolver's axle. If a torque of 1.7 to 2 times the allowable torque transfer is applied, damage will occur at the
central region of the coupling, and the resolver alone will be given the maximum load. Keep the coupling's axial
core misalignment and bending angle within the specifications.
35 +0.025
+0.009 dia.
(Recommended dimensions)
50±0.3 dia.
Four M4
Four, M4
screws
Plate thickness: 3 mm min.
33.32 +0.025
+0.009 dia.
(Recommended dimensions)
120°
52 dia.
Three M4
Three M4
Mounting hooks (included with resolver)
52 dia.
12
Plate thickness: 3 mm min.
50 dia.
6
4.4 dia.
10
2.6
Appendix B
53

Advertisement

Table of Contents
loading