Memory Allocation
I/O
Bit number
classifi-
Word
Bit
cation
In
n+2
15 to 00 Internal/external
n+3
15 to 00 Internal cam output
n+4
15 to 00
n+5
15 to 12 ---
11 to 00 Present cam angle
n+6
15 to 00 Number of process
n+7
15 to 08 ---
07 to 00 Bank being exe-
Data item
When an internal/external cam output turns ON, the appropriate bit
cam output status
turns ON. Bits 00 to 15 correspond to internal/external cam output
numbers 01 to 16.
When an internal cam output
status
turns ON, the appropriate bit turns
ON.
Not used. Set to "0."
Monitors the present resolver cam angle. 000° to 359° (3 digits BCD)
The value will be indefinite if the Resolver has been disconnected.
Monitors the number of process execution cycles (the number pro-
execution cycles
duced) per minute, in 4 digits BCD.
(see note 1)
Number of process execution cycles = Number of resolver rotations/
number of rotations required for a single process (unit: shots/min)
This value is the same as the value displayed at the Data Setting
Console in Mode 1.
Not used. Set to "0."
Monitors the bank that is presently being executed. 00 to 08 (2-digit
cuted
BCD)
Data contents
Bits 00 to 15 correspond to exter-
nal cam output numbers 17 to 32.
Bits 00 to 15 correspond to exter-
nal cam output numbers 33 to 48.
15
00
Numeric Data
(000 to 999: 3 digits BCD)
Decimal Point Position Data
1: No digits to right of decimal point
2: 1 digit to right of decimal point
4: 2 digits to right of decimal point
Section 4-1
29

Advertisement

Table of Contents
loading