Data Setting and Monitoring
Mode Selection and Data Setting Procedure
Cam Data Setting (Mode 3)
1,2,3...
Mode
no.
ON angle
1. Set the RUN/PRG selector to PRG.
If PRG is already selected, then proceed directly to (2).
2. By means of the Return Key, the Up Key, or the Down Key, select the Mode
3 indicator so that it starts to blink.
Press the Return Key, the Up Key, or the Down Key. The MODE indicator
"3" will blink. If "3" is not indicated, then use the Up Key or the Down Key
to increment or decrement the number until "3" is indicated.
3. Press the Return Key to enter the set value and select the next item.
Each time the Return Key is pressed, the set value that is blinking will be
entered and the next item to be set will start blinking.
MODE → BK → CAM → STEP → ON DATA → OFF DATA
When ON DATA or OFF DATA is selected, the respective ON or OFF indi-
cator will blink.
Each time the Reverse Key is pressed, the next item to be set will start
blinking, but in the reverse order from that shown above. If a newly set val-
ue has not already been entered with the Return Key, then pressing the re-
verse can will clear the changed data and restore the original data.
4. Use the Up Key or the Down Key to increment or decrement the set value.
Increment or decrement the set value for the item that is blinking. For data
other than BK, it is possible to change the values rapidly by holding down
the Key.
5. Press the Return Key to enter the data that has been set.
After data has been changed, the Return Key must be pressed in order for
the data to be entered. In order to clear the newly set data and return to
the original value, simply press the Reverse Key instead of the Return Key.
Then follow (3) through (5) of this procedure to set the data.
6. Press the Reverse Key to restore a blinking item to its previous lit condition.
As the Reverse Key is pressed, the items will blink in the order shown in
(3). When the mode number is blinking, pressing the Reverse Key again
will restore it to its previous lit condition and the setting operation will be
finished.
ON/OFF angle
Step no.
Cam output no.
OFF
Bank no.
angle