Wiring
Note
Circuit Diagram
Recommended Cables
and Output Blocks
1. Do not connect the load directly until trial operation has been completed.
Instead, connect to a device that will enable monitoring the external cam
output status, such as a G7TC-OC16 I/O Relay Terminal.
2. Be sure to supply power to terminals A10 and B10, or the Data Setting
Console will not operate. Power is supplied to the internal circuit and the
Data Setting Console via these terminals.
3. Although there are internal connections between terminals A9 and B9, and
between A10 and B10, a wire must still be connected to each of these ter-
minals.
The following connector set manufactured by Fujitsu is included with the Unit:
FCN-361J024-AU (soldered connector)
FCN-360C024-J2 (cover)
The following external cam output cables are recommended.
Model
G79-100C
G79-150C
G79-200C
G79-300C
G79-500C
The following Output Blocks are recommended.
Model
Resistance load
G7TC-OC16
24 VDC 5 A,
220 VAC 2 A
G7VC-OC16
24 VDC 2 A,
220 VAC 2 A
G7VC-OA16
75 to 264 VAC, 0.1 to 0.5 A
G7VC-OD16
3 to 26 VDC, 0.01 to 0.5 A
Cable length
1 m
1.5 m
2 m
3 m
5 m
Rated load
Inductive load
24 VDC 2 A,
220 VAC 1 A
24 VDC 0.8 A,
220 VAC 0.8 A
Section 2-3
+V
OUT
COM
Relays used
G7T-1112S
24 VDC
G6B-1174P-FD-US
24 VDC
G3S-201PL-PD
24 VDC
G3SD-Z01P-PD
24 VDC