Data Setting and Monitoring
Monitor Items
MODE
1
Monitoring of the number of process execution cycles
2
Monitoring of the present cam angle
Cam Setting Data and
Cam Outputs
1,2,3...
Number of Revolutions
Required for a Single
Process and Monitoring of
the Number of Process
Execution Cycles
18
Name
Set the RUN/PRG selector to RUN.
The following table shows the relation between the cam data that has been
set and the cam outputs.
Cam output no.
1
1
2
1
2
3
3
1
Angle of rotation
Cam output 1
Cam output 2
Cam output 3
The cam output turns ON at the ON angle and turns OFF at the OFF angle
minus 1°.
Cam outputs turn ON and OFF only when the Cam Positioner Unit is in opera-
tion.
The procedure for operating the Cam Positioner Unit is outlined below.
1. Set the Cam Positioner Unit's RUN/PRG selector to RUN.
2. Set banks 1 to 8 at word (n + 1).
3. Turn ON bit 00 of word n (Operation Flag).
(n = 100 + 10 x Unit no.)
During operation, the RUN indicator on the Data Setting Console will remain
lit.
The relation between the Mode 5 (number of revolutions required for a single
process) set value and the Mode 1 (monitoring of the number of process exe-
cution cycles) monitor value is as shown below.
Mode 1 monitor value = Number of resolver revolutions
If the number of revolutions required for a single process (i.e., the Mode 5 set
value) is "1," then the monitoring of the number of process execution cycles
(i.e., the Mode 1 monitor value) will indicate the number of resolver revolu-
tions.
The Mode 1 monitor value will also indicate the number produced per unit
time.
Displays the number of process execution cycles per
unit time.
Monitors the present cam angle of the resolver.
Step no.
ON angle
90
0
90
180
180
90°
180°
270°
1 revolution
Mode 5 set value
Section 3-3
Function
OFF angle
180
45
135
270
90
Direction
90°
of rotation